![background image](http://html1.mh-extra.com/html/safco/cs-i-150a/cs-i-150a_operation-and-maintenance_3253595065.webp)
CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
65 of 109
ES Out Force
Range
Value:
0-1000
Default
Value:
0
Sets the End scale output force corresponding to the maximum value of
the output voltage (10V)
ES In Force
Range
Value:
0-1000
Default
Value:
0
Sets the End scale output force corresponding to the maximum value of
the output voltage (10V)
Feed-Bk
Range
Value:
NO-SI’
Default
Value:
NO
Set / unset the PI cycle before welding pressure or force applied to the workpiece by means
of the input and output analog pressure or force.
Feed-Bk Delay Time
Range
Value:
0-20.0
Default
Value:
0
Sets the maximum time within which you must obtain feed-back loop from PI adjustment
before welding is the value in periods