CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
31 of 109
Cool time 1:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
10
It sets the pause time 1, made when the number of pulses 1 is greater than 1.
Pulses 1:
Range value:
from 1 to 10
Default
Value:
1
It sets the number of repetitions of welding 1.
Cool time 1-2:
Range value:
in cycles from 0.0 to 99.0 step 0.5
in milliseconds from 0 to 1980 step 1
Cycles Default Value:
0.0
Milliseconds Default Value:
0
It sets the cold time between weld cycle 1 and 2.
Weld time 2:
Range value:
in cycles from 0.0 to 99.0 step 0.5
in milliseconds from 0 to 1980 step 1
Cycles Default Value:
0.0 (not execute)
Milliseconds Default Value:
0
It sets the Weld time 2
Weld current 2:
Range
value:
When
in
D
‰
e V
‰
= from 50 to 999 (150A-300A)
from 100 to 999 (450A-600A
When in IK or AD = from 0.25 to Imax (150A-300A)
from 1.0 to Imax (450A-600A)
When in PK = from 0.20 to 600.0KW
When in EK = da 10 a 60000J
Default Value D‰ e V‰:
50/100
Default Value IK , AD:
0.25/1.0
Default Value PK:
0.20
Default Value EK:
10
It sets the current or the power during weld time 2.
Cool time 2:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 10 to 1980 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
10
It sets the pause time 2, made when the number of pulses 2 is greater than 1.