4.2.6
Forge
The task of forge, is activated during the course of the spot program by setting the
parameter "Forge" on "YES'" and programming the parameter "Delay Forge" with a value of
milliseconds or Cycles of delay from the start of a welding 1, when time has elapsed the set
time from the start of welding control enables the output of the forging valve and forging
pressure, if set, this value will be set on the proportional valve analogue output