Roll Motor:
Range value:
from NO,EV1 to EV4
Default
value:
NO
Set the output number to be used to start the rolls motor.
Weld Time delay:
Range value:
in cycles from 0.0 to 99.0 step 0.5
In milliseconds from 0 to 1980 step 10
Cycles Default value:
0.0
Default value in ms:
0
It sets the delay time for weld current activation, after the motor is started
Slope-Up Initial Curr.:
The parameter sets the initial current of rise ramp as a percentage of the welding current
request.
Slope-Up:
Range value:
in cycles from 0 to10
in milliseconds from 0 to 200
Cycles Default value:
0
Default value in ms:
0
It sets the rise time of the first weld current.
Pressure 1:
Range value:
da 0 a 99%
Default
value
: 0
Sets the output driving the proportional valve during welding 1
Weld time 1:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 1 to 1980 step 1
Cycles Default value:
0.5
Default value in ms:
1
It sets the weld time 1, used if cool time 1 is greater than 1, it is also used to define the test
time window, If limit control is activated.
Cool time 1:
Range value:
in cycles from 0.0 to 99.0 step 0.5
in milliseconds from 0 to 1980 step 1
Cycles Default value:
0
Default value in ms:
0
It sets the pause time 1, if different from 0, enables pulsation cycle.