To highlight the parameter to edit use the arrow keys "Up" and "Down", and with the "plus"
and "minus” change the values.
Description of the parameters in the display window.
Cycle Type
Range value
:
Spot;
Seam
The parameter sets the type of welding cycle for which the inverter is used and as a result
of this setting the parameters of the program will be available.
Any change of this setting, will reset all parameters.
Time Units
:
Range value
:
ms;
Cycle
The parameter sets the time units to display all the timings concerning the different welding
programs: cycles at 50Hz (20ms), cycles at 60Hz (16.6ms) or milliseconds.
Net Frequency:
Range value
:
50Hz;60Hz
Working Frequency
Range value
:
from 50 to 7000Hz (step 10Hz)
Working frequency values of the system CS-I
NB. After changing the working frequency in the Main Settings menu, turn off and on
again the CS-I to give effect to the frequency change. (System reset).
The calibration values are also reset with any changes of working frequency, Repeat
the calibration procedure.
I/O Card:
Range value
:
No;
YES
A setting of "Yes" this parameter, as the default, you can use the card Input Output inverter,
selecting NO all the inputs and outputs of the system are ignored, including the emergency
Input.
Init Vars:
Range value
:
No;
YES
Setting "YES" on this parameter, at the exit from the configuration menu all the parameters
of the CS-I/T and CS-I/P, exception made for those in Main settings, will be set to default
values.