29.
ERROR! BUS Current Limit exceeded
has been exceeded the maximum current
supply permitted on the bus dc inverter and
supported by the power components. you must
have less power in welding.
Alarm YES
30.
ERROR! IGBT Driver N.1
IGBT driver in ERROR to achieve maximum
current supported.
Alarm YES*
31.
ERROR! Tips voltage reading
During a welding voltage measurement tips
active, was detected outside a limit value or
zero. Check the connection.
Alarm YES
32.
ERROR! Calibration Fault
Calibration pair electrodes X failed: the current
is zero too quickly at the end of delivery.
Check the connections of the transformer and
calipers, and make sure that the electrodes do
not open before the completion of the
acquisition.
Alarm YES
33.
ERROR! Calibration, Erog. Not correct
During calibration, the different levels of
output voltage, the current is increased, or the
output voltage from the line was too low on
average. Make sure that the power connections
in power and sensors are correct, verify that the
line voltage is not too distorted and do not drop
during dispensing.
Alarm YES
34.
ERROR Calibration! Low Voltage
Dc bus voltage too low during the calibration
phase (<480V).
During the calibration phase is required to
supply line does not drop excessively. Check
the quality of the supply line and the
connection lead is used.
Alarm YES
35.
ERROR! Calibration, Low Current
Reading of current too low during the
calibration phase: the plant is presumably too
resistive. Check outgoing connections between
the inverter and transformer load, make sure
the appropriate level of force closure of the
clamp.
Alarm YES
36.
ERROR! FAN 1 or Water SV
Fault in the control circuit of the fans (if air
cooled) or solenoid water (if water cooled).
Alarm YES
37.
WARNING! Limit Max/Min. Stop!
has reached the set number of consecutive
welding parameter out of bounds. Check the
cause before continuing to weld.
Alarm YES
38.
WARNING! Reached N Spot max
you have reached the limit set by parameter
count welds. After the reset, you can continue
to weld.
Warning YES
39.
WARNING! Pair(1/2/3/4) N max steps
was reached the maximum number of steps of
the pair of electrodes in use. Reset the step
counter (front panel or from a dedicated input)
to resume welding.
Warning YES
40.
WARNING! Heat Sink. Overheating
Alarm temperature, T. > 75 ° C, from bimetal
place on the heatsink.
Alarm YES**
41.
WARNING! Heat Sink. Low temp
Alarm temperature, T. <3 ° C, by the thermal
sensor placed on the heat sink.
Warning No**