Set the Pre squeeze time.
Pressure 2:
Range
value:
from
0
to99%
Default
Value:
0
It sets the percentage of voltage for the analogical output for the proportional valve during
the squeeze time. If it is zero the previously set value is not changed.
SV Squeeze:
Range value:
from NO, 1 to 4
Default
Value:
NO
It sets number of the output to be used at Squeeze start. ( Even if the time is 0)
Squeeze:
Range value:
in cycles from 0.0 to 99.0 step 0.5
In milliseconds from 0 to 1980 step 10ms
Cycles Default Value:
0.0
Milliseconds Default Value:
0
It sets the squeeze time.
Pressure 3:
Range value:
from 0 to 99%
Default
Value:
0
It sets the percentage of voltage of the analogical output for the proportional valve.
During the Pre squeeze time, if zero the previously set value does not change
.
Pre heating time:
Range value:
in cycles from 0.0 to 99.0 step 0.5
In milliseconds from 0 to 1980 step 1
Cycles Default Value:
0.0
Milliseconds Default Value:
0
It sets the Pre heating time
.
Pre heating current:
Range
value:
When
in
D
‰
e V
‰
= from 50 to 999 (150A-300A)
from 100 to 999 (450A-600A)
When in IK, EK, AD = from 0.25 to Imax (150A-300A)
from
1.0
to
Imax
(450A-600A)
When in PK = from 0.2 to 600.0KW
Default value D‰ e V‰:
50/100
Default Value in IK , EK, AD:
0.25/1.0
Default Value in PK :
0.2
It sets the current or the pre heating power.