CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
56 of 109
4.2.14
Inputs / outputs Check.
WARNING This window contains every Function that activates the solenoid
valves,
!!TAKE ALL NECESSARY PRECAUTIONS!
!
Display window
CS-I Inputs-Outputs
Pg01:X Pg32:X Pb C:X R.St:X ENDS 0 EV1 0
Pg02:X W/NW:X Pb D:X R.Al:X OOR 0 EV2 0
Pg04:X PbCo:X PSw :X AUT 0 ION 0 EV3 0
Pg08:X Pb A:X TERM:X DTS 0 ANC 0 EV4 0
Pg16:X Pb B:X EMER:X RDY 0 ENDC 0 EV5 0
EXIT (Press +) PV 00 EV6 0
In this section you can view the status of inputs and set the outputs for solenoid valves and
signals, so you can check the status of machine wiring.
For solenoid valves from 1 to 6, The setting to 0 on inherent position switches the output
off, while the setting to 1 will enable the output if PB Com input is active.
Is possible to set the proportional valve (PV) output, at desired value, setting its parameter
from 0 to 99
The associations of the inputs and outputs are:
-INPUTS-
Pg01 = Program selection line 1
Pg02 = Program selection line 2
Pg04 = Program selection line 4
Pg08 = Program selection line 8
Pg16 = Program selection line 16
Pg32 = Program selection line 32
W/NW = external Weld/no weld
PbCo = Common Push button
Pb A = Push button A
Pb B = Push button B
Pb C = Push button C
Pb D = Push button D (Pre stroke Push button)
PSw = Pressure Switch (CP)
TERM = Thermostat
R.St = Reset Steps
R.Al = Reset Alarm
EMER = Emergency