CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
42 of 109
Weld current 1:
Range
value:
When
in
D
‰
= from 100 to 999 (150A-300A)
from 50 to 999 (450A-600A)
When in IK = from 0.25 to Imax (150A-300A)
from 1.0 to Imax (450A-600A)
Default value in D‰ e V‰:
50/100
Default value in IK :
0.25/1.0
It sets the weld current 1 value.
Pressure 2:
Range value:
da 0 a 99%
Default
value
: 0
Sets the output driving the proportional valve during welding 2
Weld time 2:
Range value:
in cycles from 0.5 to 99.0 step 0.5
in milliseconds from 1 to 1980 step 1
Cycles Default value:
0.5
Default value in ms:
1
It sets the weld time 2, used if cool time 2 is greater than 1, it is also used to define the test
time window, If limit monitoring is activated.
Cool time 2:
Range value:
in cycles from 0.0 to 99.0 step 0.5
in milliseconds from 0 to 1980 step 1
Cycles Default value:
0.0
Default value in ms:
0
It sets pause time 1, if different from 0, enables pulsation cycle.
Weld current 2:
Range
value:
When
in
D
‰
= from 100 to 999 (150A-300A)
from 50 to 999 (450A-600A)
When in IK = from 0.25 to Imax (150A-300A)
from 1.0 to Imax (450A-600A)
Default value in D‰ e V‰:
50/100
Default value in IK :
0.25/1.0
It sets the value of weld current 2
Pressure 3:
Range value:
da 0 a 99%
Default
value
: 0
Sets the output driving the proportional valve during welding 3
Weld time 3:
Range value:
in cycles from 0.5 to 99.0 step 0.5