-OUTPUTS-
EV1 = Pre-Squeeze/Squeeze/Roll motor
EV2 = Pre-Squeeze/Squeeze/Roll motor
EV3 = Pre-Squeeze/Squeeze/Roll motor
EV4 = Pre-Squeeze/Squeeze/Roll motor
EV5 = Forging/Rolls Motor
EV6 = Pre stroke
AUT = Latching output valves
DTS = Delta TS
RDY = Ready (unit ready)
ENDS = End Steps
OOR = Out Of Range
ION = Current enable
ANC = Anti parallel
ENDC = End Cycle
PV = Proportional valve
!!WARNING!!
P.S. The outlet group is feed bringing the input Pb Com or pedal 1 or pedal 2, to the
+24VP.)