![background image](http://html1.mh-extra.com/html/safco/cs-i-150a/cs-i-150a_operation-and-maintenance_3253595034.webp)
CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
34 of 109
If set to “NO”, the cycle of welding will not repeat, if set to “YES” the unit will repeat the
welding cycle, running the pre squeeze if the parameter "JMP B / A is set on B or the
squeeze if this parameter is set to "A".
Initial Blanking:
Range value:
in cycles from 0.5 to 10 step 0.5
In milliseconds from 1 to 200 STEP 1
Cycles Default Value:
0.5
Milliseconds Default Value:
1
It sets the mask time during the welding time; it has impact on display and on control.
Curr. Max, P. Max Limit:
Range value:
in D‰-V‰- from 1.0 to ImaxKA
in IK-PK-EK: from 1% to 30%
Default
Value:
1
It sets the upper limit for the monitoring of current, power.
Curr. Min, P. Min Limit:
Range
value:
in
D
‰
-V
‰
from 1.0 a ImaxKA
in IK-PK-EK: from 1% to 30%
Default
Value:
1
It sets the lower limit for the current, power, control during the weld.
Current Limit:
Range value:
only in PK = from 1 to Imaxn (n=Electrodes number)
Default
Value:
: 1
Sets the maximum current at which to arrive in PK mode must always be less than Imax 1-
2-3-4 in the calibration machine
T.Weld 1 Max:
Range value:
in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
10
In EK and AD, it sets the maximum time for a "good" .weld 1
T.Weld 1 Min:
Range value:
in cycles from 0.5 to 50.0 step 0.5
In milliseconds from 10 to 1000 step 1
Cycles Default Value:
0.5
Milliseconds Default Value:
10
In EK and AD, it sets the minimum time to obtain a "good" .weld 1