CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
28 of 109
4.2.5
Spot cycle parameters description
Electrodes:
Range value:
from 1 to 4
Default Value:
1
Matches the pair of electrodes to the parameters of the program, and on the electrode pair,
when set, makes life management, this parameter is also a reference for management of
the alarm electrodes end of life and electrode life reset.
Current:
Range
value:
NO;
YES
Default Value:
NO
If set to NO, the CS-I will perform the welding program, meeting all the times set but will not
activate the current; set to YES, will provide current flowing where required by program.
Working mode:
Range
value:
D
‰
; V
‰
; IK; with parameter VE set to “YES”, PK; EK;AD
Default Value:
D‰
Sets the mode in which the CS-I / P will make the power supply to transformer, duty-‰
(fixed) "D ‰" ‰ duty-compensated voltage Bus "V ‰" constant current "IK" in constant
power "PK", in constant energy "EK" or adaptive "AD".
Limits Check:
Range
value:
NO;
YES
Default
Value:
NO
Enables or disables the monitoring of maximum and minimum limits, on the measure in hot
times; the limits Check cannot be activated when the mode of work is AD.
Pressure 1:
Range value:
from 0 to 99%
Default
Value:
0
Sets the percentage of the voltage for the analogical output of the proportional valve, during
the pre-squeeze time.
SV Pre Squeeze:
Range value:
from NO,1 to 4
Default
Value:
NO
Set the output number to be used at Pre-Squeeze start.
Pre Squeeze:
Range value:
In cycles from 0.0 to 99.0 step 0.5
In milliseconds from 0 to 1980 step 10ms
Cycles Default Value:
0.0
Milliseconds Default Value:
0