5.8.2
End cycle
This output signals the end of the welding cycle. It is a normally open relè contact, with the
closing time adjustment using the correspondent parameter in system parameters.
It closes according to the setting of its parameter.
5.8.3
Anti-Concomitance
Normally closed contact relè it opens with the first cycle with the presence of current, and it
is deactivated when the cycle reach the hold time.
This output has the function of interlock with other welding systems.
5.8.4
End current increase (END STEPS)
This active output to +24VP, with load current up to 200mA, protected from short circuit.
When active indicates the end of the current increment steps, used to compensate the wear
of electrodes pairs.
5.8.5
Delta TS
This active output to +24VP, with load current up to 200mA, protected from short circuit.
When active indicates hot cycles are in progress.
5.8.6
Out of range
This active output to +24VP, with load current up to 200mA, protected from short circuit.
When activated, signals the exit of the thresholds set in the control of the main welding.
It is also activated in the presence of a significant deviation from the current set at welding
"Measure current out of range" or zero current.
5.8.7
CURR ON
This active output to +24VP, with load current up to 200mA, protected from short circuit.
When activated, indicates that during the hot cycle times, the CS-I will supply the current.
6.
Communications
6.1.
Connecting a printer
CS-I can be connected to a printer with a serial communication interface.
The connection is done via a serial cable, as shown in Annex B, connected to the socket 9-
pin connector present on the CS-I/P when configured in RS232 mode.
It is possible to set the communications port unit in the menu of communications.
To use the printer you must set the port as to be used for printing (PRN.) in the parameter
"Ser.Direct."
6.2.
Connecting a personal computer
The CS-I can be connect to a PC to via the serial RS-232C.
The connection can be done via a serial cable, as shown in Annex C, connected to the
socket 9-pin connector present on the CS-I/P.
You can set the communications port unit in the menu of communications.
Finally, set the serial port to the PC in the parameter "Ser.Direct."