CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
46 of 109
Set the reading and verification of the pressure switch input before (B) or after (A) the
Squeeze time.
It has no effect in Seam cycle
Latching outputs and the welding cycle occurs after the successful check of PSW input.
When the PSw input is not present, the CS-I will wait until its closure, showing in the display
state function line the message(WAIT PSw) in spot mode, or (WAITING FOR MOTOR
START) in seam mode.
After the successful reading of the contact pressure, the valves are activated and
latched (the cycle continues automatically).
This parameter is disabled in Seam mode.
JMP B/A Pre Sq.:
Range
value:
B;
A
Default value
B
In case of repeated cycles , it defines the point from which to repeat the cycle.
B= Before or A=After the Pre squeeze.
This function is disabled in Seam mode.
Log spot:
Range value:
NO; ALL; BAD
Default value
NO
CS-I can generate a report of the welds.
This can be done directly on a printer connected to the serial line or through a personal
computer with the appropriate software.
Printing of the weld values has different formats depending on the working mode stored in
the programs.
The possible settings for log of the points are three:
•
NO:
No print.
•
ALL:
prints out all welds done in spot and in Seam modes.
•
BAD:
prints only the welds out of range of control parameters, the unit must be
configured with the parameter control mode set.
If the parameter "Ser.Direct." is set to OFF, the print will be completely inhibited.
If the parameter "Ser.Direct." is different from OFF the print will have the following format:
Spot mode:
Prog. N° XX
Spot N° XX
Time 1 : XXXX ms
IRMS 1: XXX.XX KA (*)
Time 2 : XXXX ms
IRMS 2: XXX.XX KA (*)
Seam mode:
Prog. N° XX
Spot N° XX
Irms 1 : XXX.XX KA (*)
Irms 2 : XXX.XX KA (*)
Irms 3 : XXX.XX KA (*)
(*)= valid measure for Rog or CT on condition.