background image

Quick Installation Sheet | CMA-481-AEN | Page 1

Corning Optical Communications

CMA-481-AEN

HX 2.5 GHz TDD 

Indoor DAS Remote Unit 

Quick Installation Sheet

1.    The HX 2.5 GHz TDD remote is an upgrade unit and is installed in conjunction with existing HX4, HX-WCS,  

and/or MA1000/MA2000 remote. 

2.  In installations with an MA1000/MA2000 remote, an external passive module (EPM) is required  
 

(ordered separately).

3.  The HX 2.5 GHz TDD indoor unit can be installed in a 19-in communication rack or mounted on the wall  
 

(dedicated brackets are provided for both mounting options).

4.  The units are maintenance free. In the event of failure, only authorized personnel should handle the units.

5.  Only trained and qualified personnel should be allowed to install or replace this equipment.

6.  Verify that ambient temperature of the environment does not exceed 60°C (140°F)

GENERAL INFORMATION

This document describes the installation procedure of the HX 2.5 GHz TDD indoor remote unit with HX4, HX-WCS,  

and MA1000/MA2000 remote.

1. 

PACKAGE CONTENTS

The following items are required for installing the HX 2.5 GHz TDD. Please verify that the items listed below are 

included in your kit packages. If any of the listed items are missing, contact your Corning representative.

Item Description

Quantity Image

HX 2.5 GHz TDD Remote Unit:
• HX-2500-SISO* 

 

• HX-2500-MIMO† 

*SISO models include one HX-2.5 GHz TDD Module (internal) and one slot cover 

(blank panel for unoccupied HX-2.5 GHz TDD Module MIMO slot) 

†MIMO models include two HX-2.5 GHz TDD Module

1

19-in Rack Brackets (factory assembled) – (default mounting 

option) for rack-mount installations

(RT/LT)

Flat-Head Screw UNC 6-32 5/16-in (8 mm); stainless steel

12

Summary of Contents for HX 2.5 GHz TDD

Page 1: ...stall or replace this equipment 6 Verify that ambient temperature of the environment does not exceed 60 C 140 F GENERAL INFORMATION This document describes the installation procedure of the HX 2 5 GHz TDD indoor remote unit with HX4 HX WCS and MA1000 MA2000 remote 1 PACKAGE CONTENTS The following items are required for installing the HX 2 5 GHz TDD Please verify that the items listed below are inc...

Page 2: ...MUX Multiplexer ANT 1 MUX right for SISO ANT 2 MUX left for MIMO including interfaces to HX WCS HX4 and RF antennas combines signal sources additional external RF signals when connected to HX WCS and HX4 unit while providing the proper filtering into a single antenna port HX 2 5 GHz TDD Module Internal module that interfaces to the optical converter unit OCH connects via a single mode fiber pair a...

Page 3: ... racks vertical uprights as follows see Figure 3 Insert two screws halfway into the rack frame Lift the unit using the side handles and position the bottom half slots of the rack ears onto the screws Secure the unit in the rack via the remaining applicable six bracket holes using the appropriate rack nuts and screws 3B WALL MOUNT INSTALLATION IMPORTANT The wall mount installation procedures in thi...

Page 4: ... 2 5 GHz TDD unit and using six UNC 6 32 5 8 15 8 mm screws assemble the EPM onto the HX 2 5 GHz TDD unit See Figure 5 Step 4 Using ten UNC 6 32 11 mm screws for each bracket provided in HX kit assemble the wall mount brackets to the sided of the HX 2 5 GHz TDD as shown in Figure 6 Step Step 5 Referring to bracket hole dimensions in Appendix A Wall Mount Bracket Dimensions units in mm prepare the ...

Page 5: ...anded copper or 12 AWG to 10 AWG solid wire conductors Note The length of the grounding wire depends on the proximity to proper grounding facilities Phillips head screwdriver Crimping tool to crimp the grounding wire to the grounding lug Wire stripping tool to remove the insulation from the grounding wire Step 1 Use a wire stripping tool to remove approximately 0 4 in 10 9 mm of the covering from ...

Page 6: ... HX4 Step 1 Perform the HX4 service connections as follows Connect from To HX 2 5 GHz TDD WB RU N Type duplexed port HX4 ANTENNA PORT Port 1 N Type duplexed port Note For SISO installations the connections are from HX 2 5 GHz TDD ANT 1 MUX WB RU port to the HX4 ANTENNA PORT 1 For MIMO installations the MIMO 2 Stream connections are performed between the HX 2 5 GHz TDD ANT 2 MUX WB RU port and the ...

Page 7: ...e from HX 2 5 GHz TDD ANT 1 MUX WCS RU port to the HX WCS ANT 1 MUX ANT port For MIMO installations the MIMO 2 Stream connections are performed between the HX 2 5 GHz TDD ANT 2 MUX WCS RU port and the HX WCS ANT 2 MUX ANT port Step 2 Connect broadband antenna coax to HX 2 5 GHz TDD MUX module ANT port of two for MIMO models and to broadband DAS antennas See Figure 12 ATTENTION Terminate any unused...

Page 8: ... EPM front panel high band mini DIN 4 3 10 input port as shown in Figure 13 Step 2 Connect the four rear panel EPM low band N type input ports to the corresponding SCU N type ANTENNA PORTS See Figure 14 Notes The location of the SCU ANTENNA PORTS differs depending on model SCU 4 SCU 8 units antenna ports located on rear panel SCU F SCU FT antenna ports located on front panel Step 3 Connect the fou...

Page 9: ...a the fiber patch panel HX 2 5 GHz TDD supports connections to OCH WDM whereas the HX4 and HX WCS support connections to BUs Open cabinet door to access HX 2 5 GHz TDD module s with the fiber optic interface route the DL and UL fibers through the front door slot see Figure 15 and connect the fiber optic cable pigtails from splice box leading from the OCH port to the corresponding HX 2 5 GHz TDD mo...

Page 10: ...x current consumption for connector for 20 AWG 4 5 A max 5A Step 1 Make sure power switch is OFF Step 2 Open cabinet door if not already open to access power supply unit PSU Step 3 Connect the DC wires leading from the power source to the Dinkle 2ESDFM terminal block plug according to indicated pin out on the PSU DC terminal block Identify the positive and negative terminals on power source feed p...

Page 11: ... threshold Optical link level is below no link threshold Status Green Yellow Red Color according to device s overall status Service Green Red Service status is ok Any service alarm is set Ant Green Red VSWR alarm is clear VSWR alarm is set Temp Green Red Over Temp and Temperature Protection alarms are clear Over Temp or Temperature Protection alarms is set T Sync Green Red TDD sync locked TDD sync...

Page 12: ...cifications of Corning Optical Communications products without prior notification A complete listing of the trademarks of Corning Optical Communications is available at www corning com opcomm trademarks All other trademarks are the properties of their respective owners Corning Optical Communications is ISO 9001 certified 2016 2017 Corning Optical Communications All rights reserved CMA 481 AEN June...

Reviews: