background image

BoxControl compact 

Simple drive control for rolling 

and sectional doors

For the safety of persons it is important to follow these instructions!

Keep these instructions!

Caution!

Motor and 

control cable

148014801_EN_1213

BoxControl-compact_14801FR+FR+IT_1213.indb   1

24.03.2015   10:24:49

Summary of Contents for BoxControl Compact

Page 1: ...rol compact Simple drive control for rolling and sectional doors For the safety of persons it is important to follow these instructions Keep these instructions Caution Motor and control cable 148014801_EN_1213 ...

Page 2: ...ised specialist personnel The controller must be unplugged from the mains during connection work Connect controller in clockwise rotating field Swap 2 phases of the mains cable in case of incorrect rotation Check the system regularly for wear or damage The mains isolation unit must be secured against any unintentional and unauthorised reconnection and must always be accessible Keep people away fro...

Page 3: ...sing cover on the drive 7 Turn on the main switch 8 Check direction of rotation with the up button The drive has to turn in the UP direction 9 If this is not the case disconnect the controller from the mains and change over phases L1 and L2 10 Reconnect the controller with the mains and check the direction of rotation once again 11 Install the door 12 Set the limit switch See Operating instruction...

Page 4: ... v v b Wind up protection EMERGENCY STOP switch Safety switch Insert the necessary bridge when working in pulse mode 27 28 29 30 Inse bridg in pu 27 2 U V W PE PE L1 L3 L2 3 4 5 6 16 29 30 28 26 27 25 21 23 24 22 18 17 13 15 14 12 10 11 9 7 8 1 2 3 3 400V AC max 10A W1 blue U1 white V1 red 3 M 22 NHK 23 TH 13 1 1 15 14 16 2 2 4 3 18 17 L1 5 3 10 6 6 20 400 230 19 12 11 7 7 4 8 5 green yellow 1 3 6...

Page 5: ...m 7 W2 blue Drive V2 red U1 white V1 red U2 white W1 blue M 3 1 12 22 23 TH 4 Limit switch unit 1 8 NHK 5 5 4 3 2 1 3 2 4 7 6 5 L1 PE L2 L3 green yellow green yellow 1 3 2 7 6 4 5 Connection example N L3 L L1 L2 N NHK 22 M 1 23 TH L1 10 13 15 2 1 1 3 2 17 18 4 5 3 6 6 400 230 19 11 7 12 7 4 20 8 5 Change over the brake connection lead 7 from terminal 12 to 11 Important N 1 2 3 4 5 2 3 6 6 10 11 6 ...

Page 6: ...otection EMERGENCY STOP switch Safety switch ALcompact400V 15 11 07 Rei Insert the necessary bridge when working in pulse mode 27 28 29 30 L3 green yellow U V W Mains connection green yellow PE PE L1 1 3 2 L2 24 SH 30 27 SH 28 29 26 25 400V 24V DC 17 23 22 18 21 14 16 15 13 3 4 6 5 TH NHK 5 6 8 9 7 11 12 10 9 4 7 8 3 400V AC max 10A Open close Safety limit switch 1 2 Limit operating s witch Open C...

Page 7: ...22 23 TH NHK gr ye 1 2 3 4 5 6 7 8 9 Emergency crank handle Winding thermostat 2 1 3 29 30 27 28 25 26 24 23 17 22 21 18 15 16 14 13 16 18 17 14 15 13 Drive in delta configuration U2 white U1 white 3 M W2 blue V1 red V2 red W1 blue M 1 1 N 3 5 6 1 2 3 Connection example N L1 L3 L2 L N 1 230V N PE Safety devices Door edge security system Three way button Up Stop Down Momentary contact switch Up Dow...

Page 8: ...euren Fon 49 7025 13 01 Fax 49 7025 13 212 info elero de www elero com Manufacturer s declaration elero GmbH herebly declares that BoxControl comapact complies with the basic prerequisites and the other relevant provisi ons of the EC directives The complete manufacturer s declaration can be found in the download area of our website ...