![background image](http://html1.mh-extra.com/html/safco/cs-i-150a/cs-i-150a_operation-and-maintenance_3253595091.webp)
CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
91 of 109
55.
WARNING! Limit max current
you have exceeded the Maximum Current
Limit set in the program. Make sure that the
tolerances are compatible with the application,
and that you have correctly set the time on the
masking measure.
Warning No
56.
WARNING! Limit min current
you have exceeded the limit set in the
Minimum current program. Make sure that the
tolerances are compatible with the application,
and that you have correctly set the time on the
masking measure.
Warning No
CONTROL MESSAGES ON ADVANCED WELD MODES
57.
WARNING! Limit max power
[PK mode] has been exceeded Limit Maximum
Power set in the parameters of the program.
Warning No
58.
WARNING! Limit min power
[PK mode] has been exceeded limit exceeded
Minimum Power set in the parameters of the
program.
Warning No
59.
WARNING! EK T. Max reached
[EK mode] has not been reached in the energy
required set time.
Warning No
60.
WARNING! EK reached before T. Min
[EK mode] The 'Energy set in the program is
reached before the minimum time set.
Warning No
61.
WARNING! AD fail T. Min
[AD mode] During the heat cycle, has been
read a change in the gradient in a resistive time
below the threshold set time, doing a suspect
abnormality welding.
Warning No
62.
WARNING! AD fail T. Max
[AD mode] During the heat cycle, has been
read a change in the gradient in a resistive time
over the threshold set time, doing a suspect
abnormality welding
Warning No
* These alarms immediately interrupt the current erogation.
** These reports are automatically disabled.
Table 10 Alarms and warning list