![background image](http://html1.mh-extra.com/html/safco/cs-i-150a/cs-i-150a_operation-and-maintenance_3253595045.webp)
CS-I User and Maintenance, R.2.8 ENG
Safco Systems Ltd-Via Isonzo 17/b-20090 Cesano Boscone-Milan-Italy
tel. +39 024504433 Fax +39 024504321 E-mail:[email protected] Web site: www.safcosys.it
45 of 109
4.2.10
System Parameters
Display windows
CS-I System Parameters
Language
IT
(IT-EN-DE-ES)
PSw B/A Squeeze
B
(B-A)
JMP B/A Pre Sq.
B
(B-A)
Log Spots
NO
(NO-ALL-BAD)
N Bad Spots
0
(0-9)
Program IC1
0
(0-63)
Program IC2
0
(0-63)
Seq. Start Program
0
(0-63)
Seq. End Program
0
(0-63)
VE Input
NO
(NO-YES)
PV Max Volt
5
(5-10)
Pre-Stroke E.C. Open
NO
(NO-YES)
Pre-Stroke Time
1
(1-99)
Src/Prg key en
YES
(NO-YES)
S/NS key en
YES
(NO-YES)
End Cycle Type
0
(0-1-2)
End Cycle Time
10
(1-99)
EV Water presence
YES
(NO-YES)
Current source
Int
(Int-Ext-Bus)
Open Electrodes
FLT
(NO-CHK-FLT)
PSW Input
SI’
(NO-YES)
S/NS Input
SI’
(NO-YES)
Password
NO
(NO-YES)
Electrodes
YES
(NO-YES)
Current
YES
(NO-YES)
Pre Squeeze
YES
(NO-YES) (Only Spot)
Pre Heating
YES
(NO-YES) (Only Spot)
Cool time 0
YES
(NO-YES) (Only Spot)
Weld 2
YES
(NO-YES) (Only Spot)
Slope-Dw
YES
(NO-YES) (Only Spot)
Temper
YES
(NO-YES) (Only Spot)
Forge
YES
(NO-YES) (Only Spot)
Off time
YES
(NO-YES) (Only Spot)
Repeat cycle
YES
(NO-YES) (Only Spot)
EXIT (Press +)
The system parameters affect all the programs and change the characteristics of the
control.
Language:
Range value:
IT; EN; DE; ES
Default value
IT
This parameter allows the selection of one of four languages available:
Italian, English and German and Spanish (other foreign languages are available on
request).
PSw B/A Squeeze:
Range
value:
B;
A
Default value
B