You can reset the increments, dividing the current set initially, to do this simply highlight the
'"NO", after selecting the pair of electrodes in use, with "up" or "down " placed on the line
"Inc. Clear "and press the" + "(get a"yes' ").
It is reminds that at the end of the scheduled increases, the CS-l highlights the
achievement, with the message of the end steps out and activating the "End steps"
Display sub window
Auto-Step
:
Electrodes 1
Clear Inc. NO
Actual Spots 0
Actual Inc.(%) 0.0
Sub windows always present count setting of welds.
Display sub window
Counter
:
Preset 1
Enable NO
Reset NO
It is possible to stop the CS-I in a state of "not ready" after a preset number of welds.
To enable the counting in the sub window counter, proceed as follows:
• Reset the count of the welds, highlighting the “NO” on the third line "RESET", with
the down-arrow key
• Reset with key confirmation "+", (get a "YES'").
• Set the value of total points to be executed.
• Highlight with the arrow keys up / down, on the first line "PRESET", the number
• Use the Key "+" or decrease with the "-" key until the desired value is reached.
• Enable
comparison
• Highlighting with the arrow keys up / down, the second line "ENABLE" NO
• Set to YES with key confirmation "+".
Going back to the main window the count is set and enabled.
During the work cycles, the weld counter is incremented. At the comparison of the number
of welds with the value set for comparison, the CS-I stops showing the alert "number of
welds achieved" and entering to "NOT READY! ", the output" Ready "goes off.
The reset of the alarm of the counter can be made in the sub-window of the setting
counter, resetting the count or disabling it; zeroing in the main window can be performed by
pressing the "+" key , from remote , the reset can be performed via the 'input "Reset
alarms".
Sub window always display the current request from the external or bus.