4.2.11
Auto-Step
Display windows
CS-I Auto-Step
Electrodes
1
Steps: 9 Tot Spot: 15
Spots Inc(%) Tot Inc(%): 1.9
1) 1 0.1
2) 1 1.1
3) 1 0.1
4) 7 0.1
5) 1 0.1
6) 1 0.1
7) 1 0.1
8) 1 0.1
9) 1 0.1
EXIT (Press +)
The function, combined with one of four pairs of electrodes, can automatically increase the
welding current, (all hot cycles), to compensate the expected increase in the diameter of the
tips due to normal wear.
So you can define an approximated curve with a broken consisting on a maximum of 9
segments (steps).
The number of segments (Steps) is initially set to NO (no auto increment) and can be
increased up to 9.
For each step of increase set, it is displayed a new line that defines a segment made of N°
spots and a percentage current increment (Inc%).
The current will be increased at any spot, roughly the ideal curve which compensates the
wear of the tips.
When the total number of steps is reached, the CS-I indicates the necessity of electrodes
change, through the exit END STEPS and showing the message on the display.
After replacing the tips you need to reset the CS-I via the reset input STEPS, or sub-window
Auto-Step, If not reset, giving a new start cycle, the CS-I performs the welding current with
the latest set by giving again the alert message.
The maximum number of Spots settings for each step is 9999.
The total maximum number of Spots is 65535.
Everything is matched with one of four pairs of electrodes / transformer.
The output and the message will be reset by selecting the program that lists the number of
pairs of electrodes to be zero.
Electrodes:
Range value:
from 1 to 4
It selects the pair of electrodes to comply with the edited values.
Steps:
Range value:
from NO, 1 to 9
It sets the number of segments on which the increments are applied.
Spots:
Range value:
from 1 to 9999
Sets the number of points per segment on which to apply the desired percentage increase,
the sum of the points of the segments cannot exceed 65535.