Electrodes connects or disconnects in the program parameters:
Electrodes 1 (1-4)
Current connects or disconnects in the program parameters:
Current NO (NO,SI’)
Pre squeeze connects or disconnects in the program parameters:
Pressure 1 0 (0-99%)
SV Pre Squeeze NO (NO,EV1-EV4)
Pre Squeeze 0 (0-1980)
Pre Heat connects or disconnects in the program parameters:
Pressure 3
0
(0-99%)
Pre Heating time
0
(0-1980)
Pre Heating Curr.
100
(100-999‰)
Cool time 0 connects or disconnects in the program parameters:
Pressure 4
0
(0-99%)
Cold time 0
10
(10-1980)
Weld 2 connects or disconnects in the program parameters:
Cold time 1-2
0
(0-1980)
Weld Time 2
0
(0-1980)
Weld Current 2
100
(100-999‰)
Cold time 2
10
(10-1980)
Impulse 2
1
(1-10)
Cold time Sald.1-2
10
(10-1980)
Impulse Weld 1-2
1
(1-10)
Slope-DW inserisce/disinserisce nei parametri di programma:
Slope-Dw
0
(0-10)
Temper connects or disconnects in the program parameters:
Cold time 3
10
(10-1980)
Temper Time
0
(0-19980)
Temper Current
100
(100-999‰)
Forge connects or disconnects in the program parameters:
Pressure 5
0
(0-99%)
Forge
NO
(NO,YES)
Forge Delay
0
(0-1980)
Off Time connects or disconnects in the program parameters:
Off time
0
(0-1980)
Repeat Cycle connects or disconnects in the program parameters:
Repeat cycle
NO
(NO,YES)