REL1 mode is performed as in the management REL unless the non-consideration of the
limit of zero
End Scale
Range
Value:
0.0-250.0mm
Default Value:
0.0
Sets the total displacement of the transducer for a proper fit
Measure Elect. Close
Range
Value:
NO-SI’
Default
Value:
NO
Arm / disarm the parameter and its management in the cycle spots
Measure Current Cut
Range
Value:
NO-SI’
Default
Value:
NO
Arm / disarm the parameter and its management in the cycle spots
End Measure Electr.
Range
Value:
NO-SI’
Default
Value:
NO
Arm / disarm the parameter and its management in the cycle spots
Press-Force Op Mode
Range
Value:
NO-Pr-Fr
Default
Value:
NO
Sets whether to obtain the release of pressure or force on analog output
of the SM300-EXP5
ES Out Press
Range
Value:
0.0-9.9
Default
Value:
0.0
Sets the full scale output pressure corresponding to the maximum value of the output
voltage (10V)
ES In Press
Range
Value:
0.0-9.9
Default
Value:
0.0
Sets the End-scale input pressure corresponding to the maximum value
of input voltage (10V)