38
Reference Manual
00809-0100-4530, Rev DD
May 2016
3.3.2
Threaded connection
Figure 3-23. Threaded Tank Connection
1.
For tank connections with BSP/G threads, place a gasket on top of the tank flange,
or use a sealant on the threads of the tank connection.
2.
Lower the transmitter and probe into the tank.
3.
Loosen the nut that connects the transmitter housing to the probe slightly.
4.
Screw the adapter into the process connection.
5.
Rotate the transmitter housing so the cable entries/display face the desired
direction.
6.
Tighten the nut. Max torque is 30 Lbft (40 Nm).
Note
For adapters with NPT threads, pressure-tight joints require a sealant.
D
C
A
B
A.Tank connection
B.Probe
C.Nut
D.Sealant on threads or gasket (for BSP/G threads)