203
Reference Manual
00809-0100-4530, Rev DD
Safety Instrumented Systems (4-20 mA only)
May 2016
Safety Instrumented Systems (4-20 mA only)
8.3
Safety Instrumented System (SIS) Certification
This section applies to the 4-20 mA Rosemount
™
5300 Series safety-certified transmitter
used in Safety Instrumented Systems (SIS) applications. The Rosemount 5300 Series
safety-certified transmitter is certified to:
Low and high demand: Type B element
SIL 2 for random integrity @ HFT=0
SIL 3 for random integrity @ HFT=1
SIL 3 for systematic capability
Note
Refer to the Rosemount 5300 FMEDA
(1)
report for failure rate data, assessment details, and
assumptions regarding failure rate analysis.
8.4
Safety-certified identification
All Rosemount 5300 Series Transmitters must be identified as safety-certified before
installing into SIS systems.
lists the versions of the Rosemount 5300 Series
Transmitter that have been considered for the hardware assessment, to which this section
applies.
Models with the QS option code are supplied with a manufacturer’s prior use
certificate of FMEDA data.
Models with the QT option code are IEC 61508 certified by an accredited 3
rd
party
agency for use in safety instrumented systems up to SIL 3.
(For single use (1oo1) capable up to SIL 2 and for redundant use (1oo2 or 2oo3) capable
up to SIL 3.)
Table 8-1. Rosemount 5300 Series Safety-Certified Option Model Codes
1.
The Rosemount 5300 FMEDA report is accessible at
EmersonProcess.com/Rosemount-Safety
Rosemount 5300 4-20 mA HART Guided Wave Radar Level and Interface Transmitter
Hardware
Model
5301Hxxxxxxxxxxxxxx
QS or
5301Hxxxxxxxxxxxxxx
QT
Model
5302Hxxxxxxxxxxxxxx
QS or
5302Hxxxxxxxxxxxxxx
QT
Model
5303Hxxxxxxxxxxxxxx
QS or
5303Hxxxxxxxxxxxxxx
QT
Note
Transmitters will be marked with “QS” or “QT” in the model code on the label.
Software/Firmware
2.A1 - 2.J0
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...