![Rosemount 5300 Series Скачать руководство пользователя страница 369](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396369.webp)
May 2016
Reference Manual
00809-0100-4530, Rev DD
355
FAILED_ENABLE
70
Enabled FAILED_ALM alarm conditions. Corresponds bit for bit to the
FAILED_ACTIVE. A bit on means that the corresponding alarm condition is
enabled and will be detected. A bit off means the corresponding alarm
condition is disabled and will not be detected.
FAILED_MASK
71
Mask of FAILED_ALM. Corresponds bit of bit to FAILED_ACTIVE. A bit on means
that the condition is masked out from alarming.
FAILED_PRI
69
Designates the alarming priority of the FAILED_ALM.
FB_OPTION
45
Indicates which function block licensing options are enabled.
FEATURES
17
Used to show supported resource block options. The supported features are:
SOFT_WRITE_LOCK_SUPPORT, HARD_WRITE_LOCK_SUPPORT, REPORTS, and
UNICODE
FEATURES_SEL
18
Used to select resource block options.
FINAL_ASSY_NUM
54
The same final assembly number placed on the neck label.
FREE_SPACE
24
Percent of memory available for further configuration. Zero in a preconfigured
device.
FREE_TIME
25
Percent of the block processing time that is free to process additional blocks.
GRANT_DENY
14
Options for controlling access of host computers and local control panels to
operating, tuning, and alarm parameters of the block. Not used by device.
HARD_TYPES
15
The types of hardware available as channel numbers.
HARDWARE_REV
52
Hardware revision of the hardware that has the resource block in it.
HEALTH_INDEX
84
Parameter representing the overall health of the device, 100 being perfect and
1 being non-functioning. The value is based on the active PWA alarms.
ITK_VER
41
Major revision number of the inter operability test case used in certifying this
device as interoperable. The format and range are controlled by the Fieldbus
Foundation.
LIM_NOTIFY
32
Maximum number of unconfirmed alert notify messages allowed.
MAINT_ACTIVE
77
Enumerated list of maintenance conditions within a device.
MAINT_ALM
78
Alarm indicating the device needs maintenance soon. If the condition is
ignored, the device will eventually fail.
MAINT_ENABLE
75
Enabled MAINT_ALM alarm conditions. Corresponds bit for bit to the
MAINT_ACTIVE. A bit on means that the corresponding alarm condition is
enabled and will be detected. A bit off means the corresponding alarm
condition is disabled and will not be detected.
MAINT_MASK
76
Mask of MAINT_ALM. Corresponds bit of bit to MAINT_ACTIVE. A bit on means
that the condition is masked out from alarming.
MAINT_PRI
74
Designates the alarming priority of the MAINT_ALM
MANUFAC_ID
10
Manufacturer identification number – used by an interface device to locate the
DD file for the resource.
MAX_NOTIFY
31
Maximum number of unconfirmed notify messages possible.
MEMORY_SIZE
22
Available configuration memory in the empty resource. To be checked before
attempting a download.
MESSAGE_DATE
57
Date associated with the MESSAGE_TEXT parameter.
MESSAGE_TEXT
58
Used to indicate changes made by the user to the device's installation,
configuration,
or calibration.
Parameter
Index number Description
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...