![Rosemount 5300 Series Скачать руководство пользователя страница 145](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396145.webp)
131
Reference Manual
00809-0100-4530, Rev DD
May 2016
5.10.1
Application example 1
Radar level transmitter, level value
A level transmitter is measuring the level in a 33 ft. (10 m) high tank.
Figure 5-16. Situation Diagram
Solution
Table 5-12 lists the appropriate configuration settings, and Figure 5-17 illustrates the
correct function block configuration.
Table 5-12. Analog Input Function Block Configuration for a Typical Level Transmitter
Figure 5-17. Analog Input Function Block Diagram for a Typical Level Transmitter
Parameter
Configured values
L_TYPE
Direct
XD_SCALE
Not Used
OUT_SCALE
Not Used
CHANNEL
CH1: Level
33 ft
(10 m)
100%
0%
Level measurement
to another
function block
OUT_D
OUT
AI function block
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...