![Rosemount 5300 Series Скачать руководство пользователя страница 372](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396372.webp)
May 2016
Reference Manual
00809-0100-4530, Rev DD
358
FAILED_ENABLED
This parameter contains a list of failures in the device which makes the device non-opera-
tional that will cause an alert to be sent. Below is a list of the failures:
1.
Level / Interface Measurement Failure
2.
Volume / Temperature Measurement Failure
3.
Electronics Failure / Transducer Block
4.
Probe Missing
5.
Input / Output Failure
6.
Non-Volatile Memory Failure
7.
Electronics Failure / Output Board
Software Incompatibility ErrorFAILED_MASK
This parameter will mask any of the failed conditions listed in FAILED_ENABLED. A bit on
means that the condition is masked out from alarming and will not be reported.
FAILED_PRI
Designates the alerting priority of the FAILED_ALM, see
. The
default is 0 and the recommended values are between 8 and 15.
FAILED_ACTIVE
This parameter displays which of the alarms is active. Only the alarm with the highest
priority will be displayed. This priority is not the same as the FAILED_PRI parameter
described above. This priority is hard coded within the device and is not user configurable.
FAILED_ALM
Alarm indicating a failure within a device which makes the device non-operational.
MAINT_ALARMS
A maintenance alarm indicates that the device or some part of the device needs
maintenance soon. If the condition is ignored, the device will eventually fail. There are five
parameters associated with MAINT_ALARMS, they are described below.
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...