![Rosemount 5300 Series Скачать руководство пользователя страница 106](http://html1.mh-extra.com/html/rosemount/5300-series/5300-series_reference-manual_1487396106.webp)
92
Reference Manual
00809-0100-4530, Rev DD
May 2016
Tank type
You can choose one of the following options:
Strap table
Vertical cylinder
Horizontal cylinder
Vertical bullet
Horizontal bullet
Sphere
None
Strapping table
Use a strapping table if a standard tank type does not provide sufficient accuracy. Use most
of the strapping points in regions where the tank shape is non-linear. A maximum of 20
points can be added to the strapping table.
Figure 5-6. Strapping Points
Actual tank bottom may look like this.
Using only 3 strapping points results in a level-to-volume profile that is
more angular than the actual shape.
Using 10-15 of the points at the bottom of the tank yields a
level-to-volume profile that is similar to the actual tank bottom.
Содержание 5300 Series
Страница 2: ......
Страница 12: ...Reference Manual 00809 0100 4530 Rev DD Contents May 2016 xii Contents ...
Страница 94: ...80 Reference Manual 00809 0100 4530 Rev DD Electrical Installation May 2016 Electrical Installation ...
Страница 162: ...148 Reference Manual 00809 0100 4530 Rev DD Operation May 2016 Operation ...
Страница 214: ...200 Reference Manual 00809 0100 4530 Rev DD Service and Troubleshooting May 2016 Service and Troubleshooting ...
Страница 310: ...Product Certifications May 2016 Reference Manual 00809 0100 4530 Rev DD 296 Product Certifications ...
Страница 358: ...Level Transducer Block May 2016 Reference Manual 00809 0100 4530 Rev DD 344 Level Transducer Block ...
Страница 431: ...5 Reference Manual 00809 0100 4530 Rev DD May 2016 ...