APPENDIX
IMR01Y36-E2
113
Continued from the previous page.
ID
Description
Get
Set
Type
Value
Attributes
162 Manipulated output value (MV) at STOP
mode [heat-side]
Yes
Yes
INT
Refer to P. 66
163 Manipulated output value (MV) at STOP
mode [cool-side]
Yes
Yes
INT
Refer to P. 66
164 Output change rate limiter (up) [heat-side]
Yes
Yes
INT
Refer to P. 66
165 Output change rate limiter (down) [heat-side]
Yes
Yes
INT
Refer to P. 66
166 Output limiter high [heat-side]
Refer to P. 66
167 Output limiter low [heat-side]
Refer to P. 67
168 Output change rate limiter (up) [cool-side]
Yes
Yes
INT
Refer to P. 67
169 Output change rate limiter (down) [cool-side]
Yes
Yes
INT
Refer to P. 67
170 Output limiter high [cool-side]
Yes
Yes
INT
Refer to P. 67
171 Output limiter low [cool-side]
Yes
Yes
INT
Refer to P. 67
172
Unused
No
No
UINT
⎯
173
Unused
No
No
UINT
⎯
174 AT bias
Yes
Yes
INT
Refer to P. 67
175 AT cycles
Yes
Yes
INT
Refer to P. 67
176 Output value with AT turned on
Yes
Yes
INT
Refer to P. 67
177 Output value with AT turned off
Yes
Yes
INT
Refer to P. 67
178 AT differential gap time
Yes
Yes
INT
Refer to P. 67
179 Proportional band adjusting factor [heat-side] Yes
Yes
INT
Refer to P. 68
180 Integral time adjusting factor [heat-side]
Yes
Yes
INT
Refer to P. 68
181 Derivative time adjusting factor [heat-side]
Yes
Yes
INT
Refer to P. 68
182 Proportional band adjusting factor [cool-side] Yes
Yes
INT
Refer to P. 68
183 Integral time adjusting factor [cool-side]
Yes
Yes
INT
Refer to P. 68
184 Derivative time adjusting factor [cool-side]
Yes
Yes
INT
Refer to P. 68
185 Proportional band limiter (high) [heat-side]
Yes
Yes
INT
Refer to P. 68
186 Proportional band limiter (low) [heat-side]
Yes
Yes
INT
Refer to P. 68
187 Integral time limiter (high) [heat-side]
Yes
Yes
INT
Refer to P. 68
188 Integral time limiter (low) [heat-side]
Yes
Yes
INT
Refer to P. 68
189 Derivative time limiter (high) [heat-side]
Yes
Yes
INT
Refer to P. 68
190 Derivative time limiter (low) [heat-side]
Yes
Yes
INT
Refer to P. 68
191 Proportional band limiter (high) [cool-side]
Yes
Yes
INT
Refer to P. 68
192 Proportional band limiter (low) [cool-side]
Yes
Yes
INT
Refer to P. 68
193 Integral time limiter (high) [cool-side]
Yes
Yes
INT
Refer to P. 69
194 Integral time limiter (low) [cool-side]
Yes
Yes
INT
Refer to P. 69
195 Derivative time limiter (high) [cool-side]
Yes
Yes
INT
Refer to P. 69
196 Derivative time limiter (low) [cool-side]
Yes
Yes
INT
Refer to P. 69
197 Open/Close output neutral zone
Yes
Yes
INT
Refer to P. 69
198
Unused
No
No
UINT
⎯
199 Action at feedback resistance (FBR) input
break
Yes
Yes
INT
Refer to P. 69
200 Feedback adjustment
Yes
Yes
INT
Refer to P. 69
201 Control motor time
Yes
Yes
INT
Refer to P. 69
202 Integrated output limiter
Yes
Yes
INT
Refer to P. 69
203 Valve action at STOP
Yes
Yes
INT
Refer to P. 69
204 Startup tuning (ST)
Yes
Yes
INT
Refer to P. 70
205 ST proportional band adjusting factor
Yes
Yes
INT
Refer to P. 70
206 ST integral time adjusting factor
Yes
Yes
INT
Refer to P. 70
207 ST derivative time adjusting factor
Yes
Yes
INT
Refer to P. 70
Continued on the next page.