T
echnical
B
ulletin
PAGE: 17/58
Model:
Taurus-C1 / P1
Date:
21-Oct-11
No.:
RD074026
• Set SP5965-1 to "1" if you want to have the
heaters on at all times. Use this setting only if
the work area is extremely humid or
exceptionally cold.
< Decurler Unit (D544) \ Accessories >
Change in quantity of the Screw
Before the Revision
After the Revision
4. Screw (M4×8)
10
4. Screw (M4×8)
12
< Decurler Unit (D544) \ Installation >
Description of handling the Decurler unit was changed accordingly with the addition of
mylar.
Before the Revision
After the Revision
1. Prepare a place to lay the Decurler Unit.
•
Lay the Decurler Unit on a soft surface, like a
piece of cardboard or a folded drop cloth. Do
not lay the Decurler Unit on the floor.
1. Prepare a place to lay the Decurler Unit [A].
2. Lay the Decurler Unit [A] on the carton box [B] as
shown above so that the entrance gate of the
decurler unit does not touch any object or the
floor.
• Keep this position before attaching this unit to the
main machine.
• Do not lay the Decurler Unit on the floor with
the entrance gate of the decurler unit facing
downward. Otherwise, the mylars [C] on the
entrance gate may be bent or folded.