T
echnical
B
ulletin
PAGE: 9/34
Reissued: 4-Jun-15
Model:
Taurus-C1a/C1b/P1 (D074/D075)
Date:
17-Jun-14
No.:
RD074119a
3) Place the chart on a table so that the side indicated ‘First’ faces up and fold the 4
corners along the dotted lines as shown below. Do the same for the remaining 2
charts.
4) Place the chart on the contact glass so that the side indicated ‘Second’ faces up.
5) Scan the first side of all 3 charts. The software application contained in the NICE
SD card reads the distance between the trim lines and folded on all 4 corners from
the scanned data.
‘First’
faces up
‘Second’
faces up