T
echnical
B
ulletin
PAGE: 6/7
Reissued: 20-Apr-15
Model:
Taurus-C1a/C1b
Date: 20-Jun-11
No.: RD074004r
Version
Modified Points or Symptom Corrected
Proceed to Step1-2 if the current version is V1.0.
Update is not required if the current version is V1.1 or newer.
Step1-2.
Do the Fiery System Installation using the following versions.
See section "Fiery System Installation" of the service manual.
- System Software DVD Version1.1
- User Software DVD Version1.1
Note
"Fiery System Installation" will take approximately 60min. It is recommended to
update the Fiery and the mainframe simultaneously.
2. Mainframe
After completing the installation and confirming the proper function of the
system, proceed to “Step 2
-1” below.
Step2-1.
Confirm the current "System" version in SP7801.
Proceed to "Step 2-2" if the current version is either V1.02 or V1.03.
Update is not required if the current version is V1.05 or newer.
Step2-2.
Update the following 6 firmwares concurrently.
See section "Firmware Update Procedure" of the service manual.
Program Name Before the Update
After the Update
1 System/Copy
D0745773B (V1.02)
or D0745773C
(
V1.03
)
D0745773D
(
V1.05
)
2 WebSys
D0745777A
(
V1.04
)
D0745777B
(
V1.05
)
3 WebUapl
D0745778A
(
V1.00
)
D0745778B
(
V1.02
)
4 Engine
D0745404B
(
V1.05.1:04
)
D0745404C
(
V1.54:04
)
5 TDCU
D0745528B
(
V01.02:04
)
D0745528C
(
V01.03:04
)
6 Operation Panel NA
:
D0746885A
(
V1.04
)
EU
:
D0746886A
(
V1.04
)
NA
:
D0746885B
(
V1.05
)
EU
:
D0746886B
(
V1.05
)
Step2-3. Turn the machine power OFF, and then, ON after the update.
Step2-4. Modify the four SP settings as described in the table below.
SP
Description
Current value
Modified value
SP1-945-
013
Pressure Roller Fan
Strength
1
0
SP2-225-
Cleaning Speed: Col
1.20
1.00