T
echnical
B
ulletin
PAGE: 4/16
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
10-Apr-12
No.:
RD074060
6. Make another 5 copies, this time in duplex.
7. Measure the locations (c) and (d) on the back side and calculate the skew amount “(c)
– (d)” to check if skew is within the recommended range
+/- 0.4mm
.
8. Finalize the adjustment so that skew is within
+/-0.5mm
for both sides. If the skew
amount varies among the 5 copies, make additional adjustments in SP1004
(Registration Buckle Adj) and SP1005 (Reg Buckle Adj; Thick). The skew amount will
basically reduce by increasing the SP value, although the effect is dependent on paper
thickness.
This completes the procedure for achieving the recommended skew range.