T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
8-May-18
No.:
RD074142
Subject:
FSM Correction: SC570
Prepared by:
A. Tajima
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (
)
Action required
Service manual revision
Retrofit information
Tier 2
Please add the following description in
bold
on SC570 to your field service manual in
section:
6. Troubleshooting
SC Tables
SC570
SC570
D
Ozone Collection Fan Error
The ozone collection fan is the large fan on the right end the upper
horizontal dust across the back of the machine.
Fan harness disconnected or broken
Fan overload due to physical obstruction
Fan motor defective
Replace the following fans.
Ozone collection fan
Ozone exhaust fan (Y)
Ozone exhaust fan (M)
Ozone exhaust fan (C)
Ozone exhaust fan (K)
Cooling Box Ozone Exhaust Fan (This is at the rear box)
Ozone filter
If the fan did not solve, replace the harness connected to above
fans.