T
echnical
B
ulletin
PAGE: 7/9
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
20-Jul-12
No.:
RD074081
After the installation
5 Execute SP 3011-4 (Full MUSIC).
a. If MUSIC succeeds without any SC, do the following :
a-1. Clear the skew motor adjustment value by executing the following SPs. Clear
only the values of the stations that have a new skew motor.
SP2104-31 Clear Revision C
SP2104-32 Clear Revision M
SP2104-33 Clear Revision Y
a-2. Go to step 6.
b. If SC26x occurs after MUSIC, do the following:
b-1. Clear the skew motor adjustment value by executing the following SPs. Clear
only the values of the stations that have a new skew motor.
SP2104-31 Clear Revision C
SP2104-32 Clear Revision M
SP2104-33 Clear Revision Y
b-2. Execute MUSIC again.
b-3. If SC26x persists, repeat “b-1” and “b-2” until SC26x is cleared.
Note
“
b-1” and “b-2” may have to be repeated several times to clear SC26x.
6 Make sure the value(s) of the following SP(s) are “0”.
SP2104-7 Accumulation present value C
SP2104-8 Accumulation present value M
SP2104-9 Accumulation present value Y