T
echnical
B
ulletin
PAGE: 2/4
Model:
Taurus-C1a/C1b (D074/D075)
Date:
1-Apr-13
No.:
RD074101
Note 2: Procedure required BEFORE re-installing the drum cleaning unit
1. If clumps of lubricant (as shown in the photo above) are observed on the drum
surface, gently wipe off with dry cloth. Remaining clumps of lubricant could get
caught between the cleaning blade and drum surface, and cause incomplete
cleaning and generate streaks on the output images.
DO NOT
use a vacuum cleaner.
DO NOT
wipe the drum surface strongly.
2. If the cleaning unit and drum are both replaced, apply lubricant powder (B1329700)
on the drum surface as described in the service manual in the section:
Replacement and Adjustments
>
Photoconductor Development Unit (PCDU)
>
Drum Replacement
>
Installing a New Drum
3. Apply lubricant powder (D0159501) on the edges of the cleaning unit as explained in
After
Before
Make sure the powder covers this corner.