T
echnical
B
ulletin
PAGE: 2/6
Reissued:01-Dec-11
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
13-Sept-2011
No.:
RD074022a
Current specification
Optimized registration adjustment value in the sub-scan
direction is input to SP1001 for each paper weight at the
factory, which is then input manually in SP1950 and 1951
to reflect the optimum registration for each custom paper
in use.
Front Side
Back Side
Paper Weight 1
SP1001-001
SP1001-001
Paper Weight 2
SP1001-002
SP1001-002
Paper Weight 3
SP1001-003
SP1001-003
Paper Weight 4
SP1001-004
SP1001-004
Paper Weight 5
SP1001-005
SP1001-005
Paper Weight 6
SP1001-006
SP1001-006
Paper Weight 7
SP1001-007
SP1001-007
Custom Paper 1
SP1950-001
SP1951-001
Custom Paper 2
SP1950-002
SP1951-002
…
Custom Paper 100
SP1950-100
SP1951-100
For example, if “Custom Paper 1” corresponds to Paper Weight 3 (80.1 – 105.0gsm),
the value of SP1001-003 is manually input to SP1950-001 and 1951-001.
The same adjustment can also be done in the Advanced Settings instead of the SP by
applying the value to Custom Paper; “08: Adj. Image Position of Side 1 With Feed (=
SP1950)” and “09: Adj. Image Position of Side 2 With Feed (= SP1951)