T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus C1/P1 (D074/D075/M044)
Date:
13-Dec-2012
No.:
RD074096
Subject:
TCRU/ORU user manual correction
Prepared by:
K. Tsutsui
From:
1
st
PP Tech Service Sec., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other (
TCRU/ORU
operation manual
)
Tier2
Please revise the following description in the “Adjustment Item Menu Guide for
TCRU/ORU” in the following section:
2. Details of Menu Items in Adjustment Settings for Skilled Operators > 2.2 Settings Values
> 2.2.2 Image Quality Adjustment >
0202: Image Density Adjustment Execute Interval
Change the default value from “0” to “500”.
Background info
A part of Process Control was modified to enhance image quality in the upgraded firmware
that was released in fall 2011. The above default value was changed from “0” to “500” to
allow the modified Process Control to take effect. (The modified Process Control is
disabled when this value is set to “0”.)
500