T
echnical
B
ulletin
PAGE: 11/16
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
10-Apr-12
No.:
RD074060
3. Front Back Magnification Correction (IMSS)
The procedure described in this section is capable of achieving the best registration
performance available on the Taurus, which perfectly aligns the front and back image
positions with the center of the paper for EVERY
Custom Paper
by adjusting the image
size using the IMSS function.
First, adjust the image to the best position* by making adjustments in the menu items #08-
11 indicated with the red boxes in the above diagram.
Then, adjust the image size in #15-18 indicated with the blue boxes.
* If the machine starts to create the image from the position as shown
on the right, the image will be automatically centered on the paper
after this procedure is completed.