T
echnical
B
ulletin
PAGE: 12/16
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
10-Apr-12
No.:
RD074060
1. Input the default values for the following SPs.
NOTE: If the values currently applied are not defaults and need to be changed to carry out this
procedure, make sure to reset them to the original value after completing the procedure.
SP2103-001 (Erase Margin Adj: LE Width)
4.0 mm
(default)
SP2103-003 (Erase Margin Adj: Left)
2.0 mm
(default)
SP2122-102 (Erase Margin Adj: LE Plain Weight 2)
0.0 mm
(default)
2. Set the paper in use in the desired tray and register the paper as
Custom Paper
.
3. Go into the
Advanced Settings
and apply the following settings.
Advanced Settings
Set to
13
Adjust Erase Margin of Leading Edge
0
14
Adjust Erase Margin of Trailing Edge
0
4. Print 5 copies of the test pattern Trimming Area (SP2109-003-14) in b/w, duplex.
5. Measure the two locations (a) and (b) on all 5 copies and calculate the average of
each.
6. Calculate the values using the following formula.
Leading edge
: 4.0 – (average (b)) = X
1
: 4.0 – (average (b’)) = X
2
Side-to-side :
: 2.0 – (average (a)) = Y
1
2.0 – (average (a’)) = Y
2
7. Apply the above values to the following settings in the Advanced Settings menu.
Advanced Settings
Set to
8
Adj Image Position of Side 1 With Feed
X
1
9
Adj Image Position of Side 2 With Feed
X
2
10
Adj Image Position of Side 1 Across Feed
Y
1
11
Adj Image Position of Side 2 Across Feed
Y
2
8. Print 5 copies of the test pattern Trimming Area (SP2109-003-14) in b/w, duplex again
to check if the measurement is within the recommended range;
(a)(a’): 2.0 +/- 0.2 mm, (b)(b’): 4.0 +/- 0.2 mm
*
If the result is not within the range, repeat steps 4 to 7.