T
echnical
B
ulletin
PAGE: 1/1
Model:
Taurus-C1/P1 (D074/D075/M044)
Date:
15-Feb-16
No.:
RD074134
Subject:
Field Service Manual Correction (SC465)
Prepared by:
J. Ohno
From:
1st Tech Service Sect., PP Tech Service Dept.
Classification:
Troubleshooting
Mechanical
Paper path
Product Safety
Part information
Electrical
Transmit/receive
Other (
)
Action required
Service manual revision
Retrofit information
Tier 2
Please add the following detail information on the sub codes of SC465 to your FSM in
section:
Appendices
6. Troubleshooting
SC Tables
SC400: Around the Drum
No.
Sub code Type Details (Symptom, Possible Cause, Troubleshooting Procedures)
SC465
001 ~ 024
D
PTR Motor Error: Abnormal Pulses
One (or both) of the encoder sensors cannot correctly detect the
pulses.
PTR motor harness disconnected or broken
Physical obstruction blocking operation of the PTR unit
Motor or motor drive board defective
TDCU defective
41
D
PTR Motor Error: Motor Defect
Motor is physically broken or harness is disconnected.
Motor harness disconnected or broken
PTR motor defective
51
D
PTR Motor Error: Abnormal Rotation Speed
The rotation speed of the motor is not within the target range.
PTR motor harness disconnected or broken
Physical obstruction blocking operation of the PTR unit and
ITB cleaning unit
TDCU defective
PTR motor defective
52
D
PTR Motor Error: Continuous Heavy Load
The motor is turned off after detecting excess load for more than
ten seconds.
PTR motor harness disconnected or broken
Physical obstruction blocking operation of the PTR unit and
ITB cleaning unit
TDCU defective
PTR motor defective