T
echnical
B
ulletin
PAGE: 7/7
Reissued:14-Oct-14
Model:
Taurus-C1a/C1b (D074/D075)
Date:
10-Jun-14
No.:
RD074120a
E) Initializing the cleaning unit
1. Turn the main power switch ON.
2. Reset the counter of the replaced unit or part(s).
3. Close the front doors.
4. Wait for about 5 minutes until you hear an audible beep and see "Ready" displayed on
the operation panel.
5. Do the following SP according to the unit(s) replaced to clean and lubricate the
drum(s).
Replaced cleaning unit
SP
Initialized cleaning unit
All units
3032-01 (All)
All units (CMYK)
CMY cleaning units
3032-02 (CMY)
Color units (CMY)
K
3032-03 (K)
K
C
3032-04 (C)
C
M
3032-05 (M)
M
Y
3032-06 (Y)
Y
Modification of the Lubricant Bar
The lubricant bar was modified to reduce the risk of drum scratches.
One of the materials that compose the lubricant bar was eliminated, because it was found
to wear the drum. Tests have verified that the modified lubricant bar made without this
material does not generate any side effects.
The modification is applied to the lubricant bar and cleaning unit of the following part
numbers:
Lubricant Bar (only)
D0742460 COATING BAR: ASS’Y
Cleaning Unit (including the lubricant bar)
D0742332 CLEANING UNIT:ASS'Y