T
echnical
B
ulletin
PAGE: 16/58
Model:
Taurus-C1 / P1
Date:
21-Oct-11
No.:
RD074026
< Main Machine \ Tray Heaters >
Description of Tray Heaters was changed.
Before the Revision
After the Revision
There are two heater switches on the front of the
machine.
• The left switch controls the operation of the paper
bank heaters of the main machine and the LCIT
heaters.
• The right switch controls the operation of the ITB
unit heaters.
• When these switches are ON, the heaters turn on
when the main machine is turned off (or enters
energy save mode), and then turn off when the
main machine is turned on again (or leaves
energy save mode).
• When these switches are OFF, the heaters do not
turn on when the main machine is turned off (or
enters energy save mode). Both heaters are
turned OFF before the machine leaves the
factory.
• When these switches are ON and SP5965-1 is set
to "1", the heaters always remain on.
1. Open the top tray.
2. Press the left switch [A] to set up the main
machine tray bank heaters and the LCIT heaters.
3. Press the right switch [B] to set up the ITB unit
heaters.
• Do not switch on the heaters unless they are
needed.
• The heaters are recommended for use where
the humidity is high.
• Please explain to the operator that while the
heaters can effectively reduce collection of
moisture in the paper trays, they will consume
slightly more power.
• Set SP5965-1 to "1" if you want to have the
heaters on at all times. Use this setting only if
the work area is extremely humid.
There are two heater switches on the front of the
machine.
• The left switch [A] controls the operation of the
paper bank heaters of the main machine and the
LCIT heaters. This heater prevents the collection
of moisture around the paper feed trays. It should
be switched on when there the machine is
subject to high humidity.
• The right switch [B] controls the operation of the
ITB unit heaters. This heater keeps the area
around the ITB warm to facilitate cold starts. It
should be switched on in areas where it is cold,
especially in the early morning hours.
• If the temperature sensor (a thermostat) inside
the machine will automatically shut the heaters
off if the internal temperature becomes too high.
When these switches are ON:
• The heaters turn on when the main machine is
turned off (or enters energy save mode).
• The heaters turn off when the main machine is
turned on again (or leaves energy save mode).
When these switches are OFF:
• The heaters do not turn on when the main
machine is turned off (or enters energy save
mode).
• Both heaters are turned OFF before the machine
leaves the factory.
When these switches are ON and SP5965-1 is set to
"1", the heaters always remain on.
1. Open the top tray.
2. Press the left switch [A] to set up the main
machine tray bank heaters and the LCIT
heaters.
3. Press the right switch [B] to set up the ITB unit
heaters.
• Do not switch on the heaters unless they are
needed.
• Please explain to the operator that while the
heaters can improve machine performance
when humidity is high or temperatures are low,
the heaters will consume slightly more power.