T
echnical
B
ulletin
PAGE: 6/34
Reissued: 4-Jun-15
Model:
Taurus-C1a/C1b/P1 (D074/D075)
Date:
17-Jun-14
No.:
RD074119a
2.2 Common procedure for scanning test charts
1. Clean the contact glass and place the test chart so that the barcode printed on the
chart positions to the left.
2. For secure contact between the contact glass and chart, put approximately 20
sheets of paper on top of the chart. Make sure to match the corners of the paper
and contact glass.
3. Press the Scan button for the adjustment required followed by the Start key. The
scanned image will be saved as a tiff file on the SD card.
NOTE
If you are working on a printer model and cannot scan the test chart, you may use
the scanner embedded on a copier model. Take note that the serial number of the
scanned and saved tiff file name will be of the copier, not of the printer.