Version
Modified Points or Symptom Corrected
December 2012, the AC power supply unit must be installed (See RTB#
RD074097).
Firmware
Version
Engine
1.63.04 or newer
System/Copy
1.11 or newer
OpePanel.EXP
1.11 or newer
Language Install
1.07 or newer
Web Support
1.09 or newer
Specification Changes
1. The default value of the following SP was changed from "0" to "1".
SP2-830-001 AC Transcription Power Pack
Symptoms Corrected
1. Jam 009 occurs in copy operation when selecting a different paper for the
front cover.
2. SC280 occurs in copy operation when the original contains B/W and Color
and certain settings such as A3/DLT, 2-sided are applied.
1.62:04
Symptom Corrected
1. The jams on BK5030 when using CF5030
2. Invalidity of Adjustment Settings for Operators #0405 (Adjust Punch
Position With Feed Direction) when switching the main power off/on or
recovering from energy save mode
3. BK204 error on BK5030 during long running job
1.61:04
Symptom Corrected
SC36x caused by bug
Modification of toner refresh mode algorithm
(The toner yield becomes longer by new refresh mode algorithm under low
coverage conditions.)
IMPORTANT
Change the value in SP3-820-022 to “0”after upgrading the firmware.
1.60:04
Specification Changes
The default values for the following SPs were modified to reduce "shock jitter".
SP 1022-002 -70 -> -120
Symptom Corrected
The low productivity when making booklets with Plockmatic.
1.59:04
Specification Changes
The behavior of SP1-004-003 was modified to prevent Jam27/29.
Symptom Corrected
Subcodes of SC682 are not displayed.
1.58:04
Firmware requirements
Be sure to upgrade all the firmwares listed in the following table together as a
set.