Subject:
Troubleshooting Blackout of operation panel display &
SC575
Prepared by:
K. Tsutsui
From:
1st PP Tech Service Section, PP Tech Service Dep.
Classification:
Troubleshooting
Mechanical
Paper path
Part information
Electrical
Transmit/receive
Action required
Service manual revision
Retrofit information
Product Safety
Other ( )
Tier 2
SYMPTOM
1. Blackout of the operation panel display
2. SC575
CAUSE
The Pressure Roller Fan was installed incorrectly with its harness(es) jammed, resulting
in a short circuit
NOTE: Danger of fire as a result of the short circuit is prevented by the safety circuit.
The photo on the right shows the harness color coded in red protruding from the groove.
Harnesses correctly routed