RL78/G1P
CHAPTER 11 SERIAL ARRAY UNIT
R01UH0895EJ0100 Rev.1.00
380
Nov 29, 2019
Figure 11-59. Procedure for Resuming Slave Reception
Starting setting for resumption
Port manipulation
Changing setting of the SPSm register
Changing setting of the SMRmn register
Port manipulation
Writing to the SSm register
Disable clock output of the target
channel by setting a port register and a
port mode register.
Re-set the register to change the
operation clock setting.
Re-set the register to change serial mode
register mn (SMRmn) setting.
Enable clock output of the target channel
by setting a port register and a port mode
register.
Set the SSmn bit of the target channel to 1
(SEmn bit = 1: to enable operation) and
wait for a clock from the master.
(Essential)
(Selective)
(Selective)
(Essential)
(Essential)
Re-set the register to change serial
communication operation setting register
mn (SCRmn) setting.
(Selective)
Changing setting of the SCRmn register
If the OVF flag remain set, clear this
using serial flag clear trigger register mn
(SIRmn).
(Selective)
Clearing error flag
Completing resumption setting
(Essential)
Yes
No
Wait until stop the communication target
(master)
Completing master
preparations?
Remark
If PER0 is rewritten while stopping the master transmission and the clock supply is stopped, wait
until the transmission target (master) stops or transmission finishes, and then perform initialization
instead of restarting the transmission.