RL78/G1P
CHAPTER 27 ELECTRICAL SPECIFICATIONS
R01UH0895EJ0100 Rev.1.00
743
Nov 29, 2019
27.6.5 LVD circuit characteristics
LVD Detection Voltage of Reset Mode and Interrupt Mode
(T
A
=
40 to +85
C, V
PDR
V
DD
3.6 V, V
SS
= 0 V)
Parameter Symbol Conditions
MIN.
TYP.
MAX.
Unit
Detection voltage
V
LVD2
Power supply rise time
3.07
3.13
3.19
V
Power supply fall time
3.00
3.06
3.12
V
V
LVD3
Power supply rise time
2.96
3.02
3.08
V
Power supply fall time
2.90
2.96
3.02
V
V
LVD4
Power supply rise time
2.86
2.92
2.97
V
Power supply fall time
2.80
2.86
2.91
V
V
LVD5
Power supply rise time
2.76
2.81
2.87
V
Power supply fall time
2.70
2.75
2.81
V
Minimum pulse width
t
LW
300
s
Detection delay time
300
s
LVD Detection Voltage of Interrupt & Reset Mode
(T
A
=
40 to +85
C, V
PDR
V
DD
3.6 V, V
SS
= 0 V)
Parameter Symbol
Conditions
MIN.
TYP.
MAX.
Unit
Detection voltage V
LVD5
V
POC2
, V
POC1
, V
POC0
= 0, 1, 1, falling reset voltage
2.70
2.75
2.81
V
V
LVD4
LVIS1, LVIS0 = 1, 0 Rising release reset voltage
2.86
2.92
2.97
V
Falling interrupt voltage
2.80
2.86
2.91
V
V
LVD3
LVIS1, LVIS0 = 0, 1 Rising release reset voltage
2.96
3.02
3.08
V
Falling interrupt voltage
2.90
2.96
3.02
V
27.6.6 Power supply voltage rising slope characteristics
(T
A
=
40 to +85
C, V
SS
= 0 V)
Parameter Symbol Conditions
MIN.
TYP.
MAX.
Unit
Power supply voltage rising slope
S
VDD
54 V/ms
Caution Make sure to keep the internal reset state by the LVD circuit or an external reset until V
DD
reaches the
operating voltage range shown in 27.4 AC Characteristics.