RL78/G1P
CHAPTER 19 VOLTAGE DETECTOR
R01UH0895EJ0100 Rev.1.00
632
Nov 29, 2019
Figure 19-4. Timing of Voltage Detector Internal Reset Signal Generation
(Option Byte LVIMDS1, LVIMDS0 = 1, 1)
H
H
Time
LVIF flag
LVIMD flag
LVIRF flag
(RESF register)
LVILV flag
Internal reset signal
POR reset signal
LVD reset signal
Supply voltage (V
DD
)
V
LVD
V
POR
= 1.51 V (TYP.)
V
PDR
= 1.50 V (TYP.)
Lower limit of operation voltage
Not cleared
Not cleared
Cleared
Cleared by software
Cleared
Remark
V
POR
: POR power supply rise detection voltage
V