RL78/G1P
CHAPTER 9 A/D CONVERTER
R01UH0895EJ0100 Rev.1.00
276
Nov 29, 2019
9.6.6 Hardware trigger no-wait mode (select mode, one-shot conversion mode)
<1> In the stop status, the ADCE bit of A/D converter mode register 0 (ADM0) is set to 1, and the system enters the
A/D conversion standby status.
<2> After the software counts up to the stabilization wait time
Note
, the ADCS bit of the ADM0 register is set to 1 to
place the system in the hardware trigger standby status (and conversion does not start at this stage). Note that,
while in this status, A/D conversion does not start even if ADCS is set to 1.
<3> If a hardware trigger is input while ADCS = 1, A/D conversion is performed on the analog input specified by the
analog input channel specification register (ADS).
<4> When A/D conversion ends, the conversion result is stored in the A/D conversion result register (ADCR, ADCRH),
and the A/D conversion end interrupt request signal (INTAD) is generated.
<5> After A/D conversion ends, the ADCS bit remains set to 1, and the system enters the A/D conversion standby
status.
<6> If a hardware trigger is input during conversion operation, the current A/D conversion is interrupted, and
conversion restarts. The partially converted data is discarded.
<7> When the value of the ADS register is rewritten or overwritten during conversion operation, the current A/D
conversion is interrupted, and A/D conversion is performed on the analog input respecified by the ADS register.
The partially converted data is discarded.
<8> When ADCS is overwritten with 1 during conversion operation, the current A/D conversion is interrupted, and
conversion restarts. The partially converted data is discarded.
<9> When ADCS is cleared to 0 during conversion operation, the current A/D conversion is interrupted, and the
system enters the A/D conversion standby status. However, the A/D converter does not stop in this status.
<10> When ADCE is cleared to 0 while in the A/D conversion standby status, the A/D converter enters the stop status.
When ADCS = 0, inputting a hardware trigger is ignored and A/D conversion does not start.
Note
If a high-accuracy channel is selected as the analog input channel: Stabilization wait time = 0.5
s
If a standard channel is selected as the analog input channel:
Stabilization wait time = 2
s
Figure 9-22. Example of Hardware Trigger No-Wait Mode (Select Mode, One-Shot Conversion Mode)
Operation Timing
ADCS is overwritten with 1 during
A/D conversion
operation.
ADCS retains
the value 1.
ANI1
Conversion is
interrupted
and restarts.
ADCS is cleared to 0
during A/D
conversion
operation.
ADCE
Hardware
trigger
ADCS
ADS
A/D
conversion
status
ADCR,
ADCRH
INTAD
<1> ADCE is set to 1.
<2> ADCS is set to 1.
A hardware trigger
is generated.
A hardware trigger is
generated during A/D
conversion operation.
ADCE is cleared to 0.<10>
The trigger is not
acknowledged.
Trigger
standby
status
ADS is rewritten during
A/D conversion
operation
(from ANI0 to ANI1).
ANI0
<4> A/D conversion ends.
Conversion is
interrupted
and restarts.
Conversion is
interrupted
and restarts.
Conversion is
interrupted.
Stop
status
Conversion
standby
Data 1
(ANI0)
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Conversion
standby
Data 2
(ANI0)
Data 3
(ANI0)
Data 4
(ANI0)
Data 1
(ANI0)
Data 3
(ANI0)
Data 5
(ANI1)
Data 6
(ANI1)
Data 7
(ANI1)
Data 8
(ANI1)
Stop
status
Data 5
(ANI1)
Data 7
(ANI1)
<3>
<3>
<3>
<3>
<3>
<5>
<5>
<5>
<8>
<9>
<4>
<4>
<4>
<6>
<7>
<5>
The trigger is not